Tanks

Even when they look clean, tanks can be dangerous; for instance, the presence of water inside might produce corrosion, which will decrease the level of oxygen and produce hydrogen, which is a flammable gas. They might, as well, contain traces of the substance previously used in the tank, or, if they have been cleaned, they might contain the inertizing substance. In conclusion, the safety of the employees can be guaranteed only by using a multigas detector.


GASES INVOLVED

Oxygen (O2): the general principle in order to inertize a tank is to depurate the atmosphere with a gas that does not contain oxygen, preventing a possible combustion. It must be remembered that both during and after the depuration process, the atmosphere inside the tank will not contain oxygen.
Flammable gases: the combustion of flammable vapour inside the tank and the subsequent explosion can have a considerably violent reaction.
Sulphured hydrogen (H2S): usually due to the product previously contained in the tank. For instance: oil-based materials, which can produce not only flammable gases but also toxic sulphured hydrogen.
Nitrogen dioxide (NO2): usually due to the product previously contained in the tank.

EXPECTED RISKS

O2: both excess and lack of oxygen may cause important diseases, sometimes death.
Inflammable gases: in smaller concentration even than LEL with regard to the volume they explode in presence of a minimum flash source often resulting in serious consequences for people and things.
H2S: colourless gas stands out for its characteristic smell of rotten eggs. A low-concentration exposure causes eye and throat irritation, cough, acceleration of breathing and fluid formation in the respiratory ways. High concentrations kill the olfactory nerve so making impossible to smell its disgusting odour, and may cause unconsciousness in few minutes.
NO2: nitrogen dioxide irritates lung ways seriously. Even at moderate concentration in air, it causes acute cough, pains at the chest, convulsions and blood circulation failure. Also it may cause irreversible damages to lungs which may reveal themselves even many months after.

Releated Products

Leave a comment

You are commenting as guest.
CPF Industriale
CPF Industriale
P.IVA 03131150173
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.310461
Fax. 030.310465
This email address is being protected from spambots. You need JavaScript enabled to view it.
Geca srl
Geca
P.IVA 03124320171
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.3730218
Fax. 030.3730228
This email address is being protected from spambots. You need JavaScript enabled to view it.
Tecnocontrol srl
Tecnocontrol
P.IVA 03543100170
via Miglioli, 47 - 20054 Segrate (MI), Italy
Tel. 02.26922890
Fax. 02.2133734
This email address is being protected from spambots. You need JavaScript enabled to view it.
Brands:
This email address is being protected from spambots. You need JavaScript enabled to view it.
Privacy policy | Cookie policy
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. All information have indicative value, CPF Industriale srl, Geca srl and  Tecnocontrol srl reserve the right to make any change at any time without notice. For any information please contact us at the address listed above.
Unauthorized use and diffusion of information and texts supplied by CPF Industriale srl, Geca srl and Tecnocontrol srl will be pursued following the legislation.