The central unit AN750 is the main device of the fixed fume analysis system which manages signals coming from the peripheral probes installed at boilers (max. 4).
The central unit is housed in a polypropylene case with transparent polycarbonate door and rating IP65. On the unit front panel there is a blue monochromatic backlit graphic display 1/4” VGA STN (320x240 pixel).
Main card includes a 16-bit microcontroller which processes all the input data, displays them and stores them in an 16Mb Flash store.

The communication through Modbus Rtu binary protocol is done by a remote RS232 or RS485 output.
The boiler status reading is done every seconds.

logo CE nero

logo TUV nero

Standard Specifications

Power supply: 230Vca 50-60HZ (+10-15%)
Absorption: 35 VA max a 230Vac
Passive analog inputs 4-20mA: max 4 for each boiler
Active analog inputs 4-20mA: max 4 for each boiler
Consent inputs (n° 2 for each boiler): Normally Closed contact
N.3 general relays: 3A 230Vca
Work temperature and humidity: da +5° a + 45°C / da 15 a 95%
Sizes (H x L x W): 318x388x160 mm
Standards and approvals: EN ISO/IEC 17025 D.L. 3 april 2006 n° 152 - Being certified QAL1

CPF Industriale
CPF Industriale
P.IVA 03131150173
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.310461
Fax. 030.310465
This email address is being protected from spambots. You need JavaScript enabled to view it.
Geca srl
Geca
P.IVA 03124320171
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.3730218
Fax. 030.3730228
This email address is being protected from spambots. You need JavaScript enabled to view it.
Tecnocontrol srl
Tecnocontrol
P.IVA 03543100170
via Miglioli, 47 - 20054 Segrate (MI), Italy
Tel. 02.26922890
Fax. 02.2133734
This email address is being protected from spambots. You need JavaScript enabled to view it.
Brands:
This email address is being protected from spambots. You need JavaScript enabled to view it.
Privacy policy | Cookie policy
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. All information have indicative value, CPF Industriale srl, Geca srl and  Tecnocontrol srl reserve the right to make any change at any time without notice. For any information please contact us at the address listed above.
Unauthorized use and diffusion of information and texts supplied by CPF Industriale srl, Geca srl and Tecnocontrol srl will be pursued following the legislation.