fbpx

TECHNICAL SPECIFICATION:

Detection Principale
Electrochemical Cell
Self test
Every 10 Minutes
Life time
6 years
Operating Temperature
-10°C /+45°C
Humidity
15-90% - non condensing
Approval
According to EN50291-1:2010
Ip Rating
IP42
Power Supply
Long - Life lithium battery 3V
Visual Indicator
Power: Green / Alarm: Red / Fault: Yellow
Audiable
80 dB
Button
Test & Hush
Others compliances
RoHs - REACH

ALARM LEVELS

EN50291 defines the CO level, at which the device must and must not go into alarm. The higher the CO concentration, the quicker the device will give an alarm. This is based on the fact that the poisoning impact of CO is determined by CO concentration and exposure time. The alarm points ensure that the user is always warned when critical situations occur.

The alarm levels are:
  • 50 ppm: Alarm between 60 and 90 minutes
  • 100 ppm: Alarm between 10 and 40 minutes
  • 300 ppm: Alarm within 3 minutes.
CO CONCENTRATION WITHOUT ALARM BEFORE WITH ALARM BEFORE
30 ppm
120 minutes
50 ppm
60 minutes
90 minutes
100 ppm
10 minutes
40 minutes
300 ppm
3 minutes

BETA 762CO - SE325EC Carbon monoxide leak detector

BETA 762CO - SE325EC Carbon monoxide leak detector

Produced by

Request Information
Invalid Input
L'indirizzo email non è corretto
Invalid Input

Invalid Input
Errore nel controllo. Riprova, grazie.
Invalid Input
Invalid Input

Tags

BETA CO detectors warn of the presence of carbon monoxide in the environment where they are installed with an optical and acoustic signal.
At the end of the prescribed duration period, an optical signal warns to replace the unit.

logo CE nero

Standard Specifications

Power: Lithium battery 3V - 1400 mAh (NOT replaceable)
Battery life: more than 6 years (in normal operation)
Sensor life: more than 6 years in a domestic environment according to specifications.
Working temperature: -10 ° C ... + 45 ° C.
Relative humidity: 30% ... 90% UR.
Sensor operation limit: 5000 ppm max 15 minutes
Maximum storage time: 6 months
Intervention thresholds:
  • l50 ppm for 70 minutes.
  • l100 ppm for 20 minutes.
  • l300 ppm for 1 minute.
Acoustic signal: 80 dB (A) to 1 meter.
Protection degree: IP42.
Electronic self-diagnosis with anomaly signal.
The CO alarm device conforms to the European standard EN 50291-1: 2010 “Electrical devices for the detection of carbon monoxide in domestic environments”.
CPF Industriale
CPF Industriale
P.IVA 03131150173
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.310461
Fax. 030.310465
This email address is being protected from spambots. You need JavaScript enabled to view it.
Geca srl
Geca
P.IVA 03124320171
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.3730218
Fax. 030.3730228
This email address is being protected from spambots. You need JavaScript enabled to view it.
Tecnocontrol srl
Tecnocontrol
P.IVA 03543100170
via Miglioli, 47 - 20054 Segrate (MI), Italy
Tel. 02.26922890
Fax. 02.2133734
This email address is being protected from spambots. You need JavaScript enabled to view it.
Brands:
This email address is being protected from spambots. You need JavaScript enabled to view it.
Privacy policy | Cookie policy
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. All information have indicative value, CPF Industriale srl, Geca srl and  Tecnocontrol srl reserve the right to make any change at any time without notice. For any information please contact us at the address listed above.
Unauthorized use and diffusion of information and texts supplied by CPF Industriale srl, Geca srl and Tecnocontrol srl will be pursued following the legislation.