fbpx

GAS SOLENOID VALVES N.O. 550 mbar Dimensions DN65 – DN100

GAS SOLENOID VALVES N.O. 550 mbar  Dimensions DN65 – DN100
Request Information
Invalid Input
L'indirizzo email non è corretto
Invalid Input

Invalid Input
Errore nel controllo. Riprova, grazie.
Invalid Input
Invalid Input

Tags

GAS GAS solenoid valves have been designed to be combined with any gas detection system. Shut off the main outlet when an emergency situation is detected.
They have been installed at the gas piping and connected with a gas detector. Interrupt the gas flow in a danger situation.
The electro-valve is normally located after a filter, upstream of the regulation apparatus and preferably outside the measurement zone. It has been installed with the arrow stamped on the body turned towards the user appliance. To reset the solenoid valve pull the reset knob.

logo CE nero0497

logo EAC nero

Standard Specifications

Alimentation: 230 Vca – 24 Vca – 12 Vca
Body: aluminium
Working temperature: -15°C / +70°C
Closing time: < 1 sec
Max pressure: 550 mbar
Protection level: IP65
Connections: flanged UNI 2223
Weight: DN65=7,0Kg DN80=7,50Kg
DN100=9,5Kg
Type
Connection
Flow
Power
A mm
B mm
power supply
VR560/12
DN65 2” ½
170 (mc/H)
19 W
350
346
12Vcc
VR560
DN65 2” ½
170 (mc/H)
17 VA
350
346
230Vac
VR570/12
DN80 3”
170 (mc/H)
19 W
350
346
12Vcc
VR570
DN80 3”
170 (mc/H)
17 VA
350
346
230Vac
VR580/12
DN100 4”
280 (mc/H)
19 W
350
346
12Vcc
VR580
DN100 4”
280 (mc/H)
17 VA
350
346
230Vac

Gas solenoid Valves Pressure Drop table

CPF Industriale
CPF Industriale
P.IVA 03131150173
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.310461
Fax. 030.310465
This email address is being protected from spambots. You need JavaScript enabled to view it.
Geca srl
Geca
P.IVA 03124320171
via E.Fermi, 98 - 25064 Gussago (BS), Italy
Tel. 030.3730218
Fax. 030.3730228
This email address is being protected from spambots. You need JavaScript enabled to view it.
Tecnocontrol srl
Tecnocontrol
P.IVA 03543100170
via Miglioli, 47 - 20054 Segrate (MI), Italy
Tel. 02.26922890
Fax. 02.2133734
This email address is being protected from spambots. You need JavaScript enabled to view it.
Brands:
This email address is being protected from spambots. You need JavaScript enabled to view it.
Privacy policy | Cookie policy
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. All information have indicative value, CPF Industriale srl, Geca srl and  Tecnocontrol srl reserve the right to make any change at any time without notice. For any information please contact us at the address listed above.
Unauthorized use and diffusion of information and texts supplied by CPF Industriale srl, Geca srl and Tecnocontrol srl will be pursued following the legislation.